Iei keypad manual4/22/2024 IEI 232e Standalone Installation/Programming Manual 4.6 Installing the Plug-On Relay Board The Plug-On relay board contains the alarm shunt, propped door, and forced door relays. Connect the white/orange (loop common) to the common on the REX device and the common the door switch. Connect the brown wire (REX Input) to the normally open connection the REX device. IEI 232e Standalone Installation/Programming Manual 4.5 Wiring Remote Trigger as Request to Exit (REX) Button and Door Contacts Use the following steps to connect the 232e keypad to a normally open REX device and normally closed door switch: 1. Figure 7 Shunting a Normally Closed Zone Document # 6054004, Rev. Connect the green wire (normally open) to the normally closed connection on the door position switch. Connect the blue wire (common) to the common connection on the door position switch. IEI 232e Standalone Installation/Programming Manual Figure 6 Wiring 232e Keypad to Electric Strike 4.4 Shunting a Normally Closed Zone Use the following steps to employ the 232e keypad to shunt a normally closed zone: 1. Connect the black wire (V-) to the negative on the Maglock, and then connect them to the negative on the power supply. Connect the gray wire (normally closed) to the positive on the maglock. Connect the red wire (V+) to the blue wire (common), and then connect them to the positive on the power supply. IEI 232e Standalone Installation/Programming Manual 4.2 Wiring the 232e Keypad to a Maglock (FailSafe) Use the following steps to connect the 232e keypad to a Maglock (Fail-Safe): 1. Wiring Figure 4 232e Connector and Wire Harness 4. IEI 232e Standalone Installation/Programming Manual 4. Mounting height can vary depending on requirements. To properly size the mounting and wire access hole, use the installation template on the last page of this manual and on the unit’s container. In addition, it can be flush mounted directly to the wall surface by cutting a hole in the wall. Mounting The keypad is designed to be flush mounted using a standard singlegang electrical box. IEI 232e Standalone Installation/Programming Manual 3. IEI 232e Standalone Installation/Programming Manual Figure 1 Mounting a Sentrol 3012 Tamper Switch Figure 2 Mounting a Sentrol 3025T Tamper Switch Document # 6054004, Rev. In addition, all wires and cables used must be stranded and shielded U.L. This system must be installed in accordance with the National Electrical code (NFPA70), local codes, and the authorities having jurisdiction. This section contains information regarding all the requirements necessary to meet U.L. IEI 232e Standalone Installation/Programming Manual Section 3. Specifications Parameter Range/Description Voltage 10-30 VDC, 12-24 VAC Current and Add 20 mA for each alarm relay Environment Indoor and Outdoor Temperature Tolerance -20 ☏ to 130 ☏ Dimensions 4.5" H x 2.75" W x 0.60" D Main Relay (Form C) Alarm Relays: Alarm Shunt, Propped Door, Forced Door Relays (Form C) Document # 6054004, Rev. IEI 232e Standalone Installation/Programming Manual 2. IEI 232e Standalone Installation/Programming Manual 1. Requirements Specifications Mounting Wiring 5.1 Wire Harness Configuration 5.2 Wiring the 232e Keypad to a Maglock (Fail-Safe) 5.3 Wiring the 232e Keypad to an Electric Strike (Fail-Secure) 5.4 Shunting a Normally Closed Zone 5. *LAN/WAN connectivity requires the purchase of the LAN/WAN device, Model: SEG-1.IEI 232e StandaloneTM Keypad Installation/ Programming Manual Contents Section 1: Section 2: Section 3: Section 4: Section 5: Section 6: Section 7: Section 8: Section 9: Section 10: Features and Product Description 1.1 Features 1.2 Product Description U.L. The proximity reader is capable of being mounted up to a maximum of 10 feet away from the prox.pad plus. The prox.pad plus can be directly mounted to a single gang electrical box or to most flat surfaces. By utilizing the proximity reader and keypad together, a higher level of security is achieved by requiring both to grant access. The software can communicate to the prox.pad plus either through a 485 connection, or on a LAN/WAN using the SEG-1 TCP/IP communication device. The software allows the management of people and doors through easy to create reports and step by step wizard assisted expanded feature functionality. The prox.pad plus when used on it’s own provides standard access control functionality with the use of it’s two relays and two inputs for request to exit and door position, and enhanced system functionality when used with Hub Manager® Professional software. Prox.pad™ plus is a fully integrated PC managed single door access system with a stand alone proximity reader and keypad.
0 Comments
Leave a Reply.AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |